Kantor
H.L., Briggs
R.W., Balaban
R.S.; In vivo 31P nuclear magnetic resonance measurements in canine heart using a catheter-coil. Circ Res. 55 1984:261-266.
Hurst
G.C., Hua
J., Duerk
J.L., Cohen
A.M.; Intravascular (catheter) NMR receiver probe: preliminary design analysis and application to canine iliofemoral imaging. Magn Reson Med. 24 1992:343-357.
Martin
A.J., Plewes
D.B., Henkelman
R.M.; MR imaging of blood vessels with an intravascular coil. J Magn Reson Imaging. 2 1992:421-429.
Nordbeck
P., Bauer
W.R., Fidler
F.; Feasibility of real-time MRI with a novel carbon catheter for interventional electrophysiology. Circ Arrhythmia Electrophysiol. 2 2009:258-267.
Raval
A.N., Telep
J.D., Guttman
M.A.; Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in swine. Circulation. 112 2005:699-706.
Omary
R.A., Green
J.D., Schirf
B.E., Li
Y., Finn
J.P., Li
D.; Real-time magnetic resonance imaging-guided coronary catheterization in swine. Circulation. 107 2003:2656-2659.
Serfaty
J.M., Yang
X., Foo
T.K., Kumar
A., Derbyshire
A., Atalar
E.; MRI-guided coronary catheterization and PTCA: a feasibility study on a dog model. Magn Reson Med. 49 2003:258-263.
Spuentrup
E., Ruebben
A., Schaeffter
T., Manning
W.J., Gunther
R.W., Buecker
A.; Magnetic resonance-guided coronary artery stent placement in a swine model. Circulation. 105 2002:874-879.
Manke
C., Nitz
W.R., Djavidani
B.; MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study. Radiology. 219 2001:527-534.
Elgort
D.R., Hillenbrand
C.M., Zhang
S.; Image-guided and -monitored renal artery stenting using only MRI. J Magn Reson Imaging. 23 2006:619-627.
Raman
V.K., Karmarkar
P.V., Guttman
M.A.; Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine. J Am Coll Cardiol. 45 2005:2069-2077.
Eggebrecht
H., Kuhl
H., Kaiser
G.M.; Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection. Eur Heart J. 27 2006:613-620.
Krueger
J.J., Ewert
P., Yilmaz
S.; Magnetic resonance imaging-guided balloon angioplasty of coarctation of the aorta: a pilot study. Circulation. 113 2006:1093-1100.
Raval
A.N., Karmarkar
P.V., Guttman
M.A.; Real-time magnetic resonance imaging-guided endovascular recanalization of chronic total arterial occlusion in a swine model. Circulation. 113 2006:1101-1107.
Anderson
K.J., Leung
G., Dick
A.J., Wright
G.A.; Forward-looking intravascular orthogonal-solenoid coil for imaging and guidance in occlusive arterial disease. Magn Reson Med. 60 2008:489-495.
Kee
S.T., Ganguly
A., Daniel
B.L.; MR-guided transjugular intrahepatic portosystemic shunt creation with use of a hybrid radiography/MR system. J Vasc Interv Radiol. 16 2005:227-234.
Arepally
A., Karmarkar
P.V., Weiss
C., Atalar
E.; Percutaneous MR imaging-guided transvascular access of mesenteric venous system: study in swine model. Radiology. 238 2006:113-118.
Raval
A.N., Karmarkar
P.V., Guttman
M.A.; Real-time MRI guided atrial septal puncture and balloon septostomy in swine. Catheter Cardiovasc Interv. 67 2006:637-643.
Elagha
A.A., Kocaturk
O., Guttman
M.A.; Real-time MR imaging-guided laser atrial septal puncture in swine. J Vasc Interv Radiol. 19 2008:1347-1353.
Buecker
A., Spuentrup
E., Grabitz
R.; Magnetic resonance-guided placement of atrial septal closure device in animal model of patent foramen ovale. Circulation. 106 2002:511-515.
Rickers
C., Jerosch-Herold
M., Hu
X.; Magnetic resonance image-guided transcatheter closure of atrial septal defects. Circulation. 107 2003:132-138.
Schalla
S., Saeed
M., Higgins
C.B., Weber
O., Martin
A., Moore
P.; Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: assessment and validation in a large animal model. J Magn Reson Imaging. 21 2005:204-211.
Kuehne
T., Yilmaz
S., Meinus
C.; Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: feasibility study in swine. J Am Coll Cardiol. 44 2004:2247-2249.
McVeigh
E.R., Guttman
M.A., Lederman
R.J.; Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach. Magn Reson Med. 56 2006:958-964.
Bracken
J.A., Komljenovic
P., Lillaney
P.V., Fahrig
R., Rowlands
J.A.; Closed-bore XMR (CBXMR) systems for aortic valve replacement: X-ray tube imaging performance. Med Phys. 36 2009:1086-1097.
Lederman
R.J., Guttman
M.A., Peters
D.C.; Catheter-based endomyocardial injection with real-time magnetic resonance imaging. Circulation. 105 2002:1282-1284.
Corti
R., Badimon
J., Mizsei
G.; Real time magnetic resonance guided endomyocardial local delivery. Heart. 91 2005:348-353.
Barbash
I.M., Leor
J., Feinberg
M.S.; Interventional magnetic resonance imaging for guiding gene and cell transfer in the heart. Heart. 90 2004:87-91.
Dick
A.J., Guttman
M.A., Raman
V.K.; Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine. Circulation. 108 2003:2899-2904.
Saeed
M., Martin
A., Jacquier
A.; Permanent coronary artery occlusion: cardiovascular MR imaging is platform for percutaneous transendocardial delivery and assessment of gene therapy in canine model. Radiology. 249 2008:560-571.
Kraitchman
D.L., Heldman
A.W., Atalar
E.; In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction. Circulation. 107 2003:2290-2293.
Andreassi
M.G., Ait-Ali
L., Botto
N., Manfredi
S., Mottola
G., Picano
E.; Cardiac catheterization and long-term chromosomal damage in children with congenital heart disease. Eur Heart J. 27 2006:2703-2708.
Vano
E., Gonzalez
L., Fernandez
J.M., Haskal
Z.J.; Eye lens exposure to radiation in interventional suites: caution is warranted. Radiology. 248 2008:945-953.
Goldstein
J.A., Balter
S., Cowley
M., Hodgson
J., Klein
L.W.; Occupational hazards of interventional cardiologists: prevalence of orthopedic health problems in contemporary practice. Catheter Cardiovasc Interv. 63 2004:407-411.
Razavi
R., Hill
D.L., Keevil
S.F.; Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet. 362 2003:1877-1882.
Muthurangu
V., Taylor
A., Andriantsimiavona
R.; Novel method of quantifying pulmonary vascular resistance by use of simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow. Circulation. 110 2004:826-834.
Kuehne
T., Yilmaz
S., Schulze-Neick
I.; Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension. Heart. 91 2005:1064-1069.
Kuehne
T., Saeed
M., Higgins
C.B.; Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology. 226 2003:475-481.
Khambadkone
S., Coats
L., Taylor
A.; Percutaneous pulmonary valve implantation in humans: results in 59 consecutive patients. Circulation. 112 2005:1189-1197.
Dickfeld
T., Calkins
H., Zviman
M.; Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time. Circulation. 108 2003:2407-2413.
Dickfeld
T., Kato
R., Zviman
M.; Characterization of radiofrequency ablation lesions with gadolinium-enhanced cardiovascular magnetic resonance imaging. J Am Coll Cardiol. 47 2006:370-378.
McGann
C.J., Kholmovski
E.G., Oakes
R.S.; New magnetic resonance imaging-based method for defining the extent of left atrial wall injury after the ablation of atrial fibrillation. J Am Coll Cardiol. 52 2008:1263-1271.
Susil
R.C., Yeung
C.J., Halperin
H.R., Lardo
A.C., Atalar
E.; Multifunctional interventional devices for MRI: a combined electrophysiology/MRI catheter. Magn Reson Med. 47 2002:594-600.
Dukkipati
S.R., Mallozzi
R., Schmidt
E.J.; Electroanatomic mapping of the left ventricle in a porcine model of chronic myocardial infarction with magnetic resonance-based catheter tracking. Circulation. 118 2008:853-862.
Krueger
S., Lips
O., David
B.; Towards MR-guided EP interventions using an RF-safe concept. J Cardiovasc Magn Reson. 11
(Suppl)
2009:O84
Nazarian
S., Kolandaivelu
A., Zviman
M.M.; Feasibility of real-time magnetic resonance imaging for catheter guidance in electrophysiology studies. Circulation. 118 2008:223-229.
Gutierrez
L.F., Silva
R., Ozturk
C.; Technology preview: X-ray fused with magnetic resonance during invasive cardiovascular procedures. Catheter Cardiovasc Interv. 70 2007:773-782.
de Silva
R., Gutierrez
L.F., Raval
A.N., McVeigh
E.R., Ozturk
C., Lederman
R.J.; X-ray fused with magnetic resonance imaging (XFM) to target endomyocardial injections: validation in a swine model of myocardial infarction. Circulation. 114 2006:2342-2350.
Ratnayaka
K., Raman
V.K., Faranesh
A.Z.; Antegrade percutaneous closure of membranous ventricular septal defect using X-ray fused with magnetic resonance imaging. J Am Coll Cardiol Intv. 2 2009:224-230.
Rhode
K.S., Hill
D.L., Edwards
P.J.; Registration and tracking to integrate X-ray and MR images in an XMR facility. IEEE Trans Med Imaging. 22 2003:1369-1378.
Rhode
K.S., Sermesant
M., Brogan
D.; A system for real-time XMR-guided cardiovascular intervention. IEEE Trans Med Imaging. 24 2005:1428-1440.
King
A.P., Boubertakh
R., Rhode
K.S.; A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures. Med Image Anal. 13 2009:419-431.
Tronnier
V.M., Wirtz
C.R., Knauth
M.; Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery. Neurosurgery. 40 1997:891-902.
Martin
A.J., Larson
P.S., Ostrem
J.L.; Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging. Magn Reson Med. 54 2005:1107-1114.
Weiss
C.R., Nour
S.G., Lewin
J.S.; MR-guided biopsy: a review of current techniques and applications. J Magn Reson Imaging. 27 2008:311-325.
Rieke
V., Butts Pauly
K.; MR thermometry. J Magn Reson Imaging. 27 2008:376-390.
Smith
K.A., Carrino
J.; MRI-guided interventions of the musculoskeletal system. J Magn Reson Imaging. 27 2008:339-346.
Cleary
K., Melzer
A., Watson
V., Kronreif
G., Stoianovici
D.; Interventional robotic systems: applications and technology state-of-the-art. Minim Invasive Ther Allied Technol. 15 2006:101-113.
Hoult
D.I., Saunders
J.K., Sutherland
G.R.; The engineering of an interventional MRI with a movable 1.5 Tesla magnet. J Magn Reson Imaging. 13 2001:78-86.
Griswold
M.A., Jakob
P.M., Heidemann
R.M.; Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 47 2002:1202-1210.
Kellman
P., Epstein
F.H., McVeigh
E.R.; Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med. 45 2001:846-852.
Pruessmann
K.P., Weiger
M., Scheidegger
M.B., Boesiger
P.; SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 42 1999:952-962.
Guttman
M.A., Ozturk
C., Raval
A.N.; Interventional cardiovascular procedures guided by real-time MR imaging: an interactive interface using multiple slices, adaptive projection modes and live 3D renderings. J Magn Reson Imaging. 26 2007:1429-1435.
Santos
J.M., Wright
G.A., Pauly
J.M.; Flexible real-time magnetic resonance imaging framework. Conf Proc IEEE Eng Med Biol Soc. 2 2004:1048-1051.
Yutzy
S.R., Duerk
J.L.; Pulse sequences and system interfaces for interventional and real-time MRI. J Magn Reson Imaging. 27 2008:267-275.
Schirra
C.O., Weiss
S., Krueger
S.; Toward true 3D visualization of active catheters using compressed sensing. Magn Reson Med. 62 2009:341-347.
George
A., Derbyshire
J., Saybasili
H.; Fast, robust 3D visualization and automatic slice repositioning (“snap-to”) for MR-guided interventions using active device “profiling.”. Paper presented at: ISMRM 17th Annual Scientific Meeting April 18 to 24 2009 Honolulu, HI
Elgort
D.R., Wong
E.Y., Hillenbrand
C.M., Wacker
F.K., Lewin
J.S., Duerk
J.L.; Real-time catheter tracking and adaptive imaging. J Magn Reson Imaging. 18 2003:621-626.
Patil
S., Bieri
O., Jhooti
P., Scheffler
K.; Automatic slice positioning (ASP) for passive real-time tracking of interventional devices using projection-reconstruction imaging with echo-dephasing (PRIDE). Magn Reson Med. 62 2009:935-942.
Rubin
D.L., Ratner
A.V., Young
S.W.; Magnetic susceptibility effects and their application in the development of new ferromagnetic catheters for magnetic resonance imaging. Invest Radiol. 25 1990:1325-1332.
Bakker
C.J., Hoogeveen
R.M., Weber
J., van Vaals
J.J., Viergever
M.A., Mali
W.P.; Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions. Magn Reson Med. 36 1996:816-820.
Omary
R.A., Unal
O., Koscielski
D.S.; Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. J Vasc Interv Radiol. 11 2000:1079-1085.
Miquel
M.E., Hegde
S., Muthurangu
V.; Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients. Magn Reson Med. 51 2004:988-995.
Kozerke
S., Hegde
S., Schaeffter
T., Lamerichs
R., Razavi
R., Hill
D.L.; Catheter tracking and visualization using 19F nuclear magnetic resonance. Magn Reson Med. 52 2004:693-697.
Magnusson
P., Johansson
E., Mansson
S.; Passive catheter tracking during interventional MRI using hyperpolarized 13C. Magn Reson Med. 57 2007:1140-1147.
Dharmakumar
R., Koktzoglou
I., Tang
R., Harris
K.R., Beohar
N., Li
D.; Off-resonance positive contrast imaging of a passive endomyocardial catheter in swine. Phys Med Biol. 53 2008:N249-N257.
Edelman
R.R., Storey
P., Dunkle
E.; Gadolinium-enhanced off-resonance contrast angiography. Magn Reson Med. 57 2007:475-484.
Krueger
S., Schmitz
S., Weiss
S.; An MR guidewire based on micropultruded fiber-reinforced material. Magn Reson Med. 60 2008:1190-1196.
Mekle
R., Hofmann
E., Scheffler
K., Bilecen
D.; A polymer-based MR-compatible guidewire: a study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA). J Magn Reson Imaging. 23 2006:145-155.
Dumoulin
C.L., Souza
S.P., Darrow
R.D.; Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med. 29 1993:411-415.
Ocali
O., Atalar
E.; Intravascular magnetic resonance imaging using a loopless catheter antenna. Magn Reson Med. 37 1997:112-118.
Kocaturk
O., Kim
A.H., Saikus
C.E.; Active two-channel 0.035'' guidewire for interventional cardiovascular MRI. J Magn Reson Imaging. 30 2009:461-465.
Kuehne
T., Fahrig
R., Butts
K.; Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations. J Magn Reson Imaging. 17 2003:620-624.
Quick
H.H., Zenge
M.O., Kuehl
H.; Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization. Magn Reson Med. 53 2005:446-455.
Eggers
H., Weiss
S., Boernert
P., Boesiger
P.; Image-based tracking of optically detunable parallel resonant circuits. Magn Reson Med. 49 2003:1163-1174.
Wong
E.Y., Zhang
Q., Duerk
J.L., Lewin
J.S., Wendt
M.; An optical system for wireless detuning of parallel resonant circuits. J Magn Reson Imaging. 12 2000:632-638.
Celik
H., Uluturk
A., Tali
T., Atalar
E.; A catheter tracking method using reverse polarization for MR-guided interventions. Magn Reson Med. 58 2007:1224-1231.
Pictet
J., Meuli
R., Wicky
S., van der Klink
J.J.; Radiofrequency heating effects around resonant lengths of wire in MRI. Phys Med Biol. 47 2002:2973-2985.
Ladd
M.E., Quick
H.H.; Reduction of resonant RF heating in intravascular catheters using coaxial chokes. Magn Reson Med. 43 2000:615-619.
Weiss
S., Vernickel
P., Schaeffter
T., Schulz
V., Gleich
B.; Transmission line for improved RF safety of interventional devices. Magn Reson Med. 54 2005:182-189.
Fandrey
S., Weiss
S., Muller
J.; Development of an active intravascular MR device with an optical transmission system. IEEE Trans Med Imaging. 27 2008:1723-1727.