Atherosclerotic and Thrombogenic Neointima Formed Over Sirolimus Drug-Eluting StentAn Angioscopic Study
Tomoaki Higo, MD,
Yasunori Ueda, MD, PhD*,
Jota Oyabu, MD,
Katsuki Okada, MD,
Mayu Nishio, MD, PhD,
Akio Hirata, MD, PhD,
Kazunori Kashiwase, MD, PhD,
Nobuyuki Ogasawara, MD,
Shinichi Hirotani, MD, PhD,
Kazuhisa Kodama, MD, PhD
Cardiovascular Division, Osaka Police Hospital, Osaka, Japan
* Reprint requests and correspondence: Dr. Yasunori Ueda, Cardiovascular Division, Osaka Police Hospital, 10-31 Kitayama-cho, Tennoji-ku, Osaka 543-0035, Japan (Email: ueda{at}oph.gr.jp).
Objectives: We sought to examine by angioscopy the neointima formation and thrombogenic potential of the neointima after deployment of a drug-eluting stent (DES).
Background: Late stent thrombosis after DES implantation, a major safety concern, has been associated with poor strut coverage by neointima. Intracoronary angioscopy provides a method for visual evaluation of stent coverage by neointima and detection of thrombus in the stented coronary segment.
Methods: Patients undergoing implantation of a sirolimus DES (n = 57) were serially examined by angioscopy immediately after (baseline) and again at 10 months (follow-up) after implantation. The angioscopic color grade of the neointima from white to yellow was assessed in a semiquantitative manner. Stent coverage was classified into not covered (Grade 0), covered by a thin layer (Grade 1), or buried under neointima (Grade 2). The thrombogenic potential of the neointima was evaluated by the prevalence of thrombus on the neointima.
Results: The maximum yellow color grade of the neointima within DES-implanted lesions increased significantly from baseline to follow-up (1.4 ± 1.1 vs. 1.9 ± 0.6, p = 0.0008). Even among lesions without yellow color at baseline, yellow color was detected in 94% (17 of 18) of lesions at follow-up. The prevalence of thrombus was significantly higher on the yellow than on the white neointimal areas. Thrombus was detected on yellow and/or Grade-0/1 neointima, but never on the white Grade-2 neointima.
Conclusions: Sirolimus DES promoted formation of atherosclerotic yellow neointima in the stent-implanted lesion at 10-month follow-up. Thrombus was detected more often on the yellow area than on the white area and was never detected where a stent was buried under white neointima. These data suggest that the increased potential risk of late stent thrombosis in DES lesions may be due to the newly formed yellow neotima and cholesterol-laden plaque.
Key Words: drug-eluting stent neointima yellow neointima thrombus
|
Abbreviations and Acronyms
| | ACS = acute coronary syndrome | | BMS = bare-metal stent(s) | | DES = drug-eluting stent(s) | | PCI = percutaneous coronary intervention |
|
Related Article
-
One Step Forward and Two Steps Back With Drug-Eluting-Stents: From Preventing Restenosis to Causing Late Thrombosis and Nouveau Atherosclerosis
- Gaku Nakazawa, Marc Vorpahl, Aloke V. Finn, Jagat Narula, and Renu Virmani
J. Am. Coll. Cardiol. Img. 2009 2: 625-628.
[Full Text]
[PDF]
This article has been cited by other articles:

|
 |

|
 |
 
M. Nakano, M. Vorpahl, F. Otsuka, M. Taniwaki, S. K. Yazdani, A. V. Finn, E. R. Ladich, F. D. Kolodgie, and R. Virmani
Ex Vivo Assessment of Vascular Response to Coronary Stents by Optical Frequency Domain Imaging
J. Am. Coll. Cardiol. Img.,
January 1, 2012;
5(1):
71 - 82.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Guagliumi, V. Sirbu, G. Musumeci, R. Gerber, G. Biondi-Zoccai, H. Ikejima, E. Ladich, N. Lortkipanidze, A. Matiashvili, O. Valsecchi, et al.
Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis: Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging
J. Am. Coll. Cardiol. Intv.,
January 1, 2012;
5(1):
12 - 20.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. C. Lowe, J. Narula, J. G. Fujimoto, and I.-K. Jang
Intracoronary Optical Diagnostics: Current Status, Limitations, and Potential
J. Am. Coll. Cardiol. Intv.,
December 1, 2011;
4(12):
1257 - 1270.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. V. Finn, Y. Chandrashekhar, and J. Narula
IVUS and OCT: Either or Survivor ...
J. Am. Coll. Cardiol. Img.,
September 1, 2011;
4(9):
1047 - 1049.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J.-M. Cho, I.-S. Sohn, C.-J. Kim, and I.-K. Jang
Vulnerable Plaque Inside Stent
J. Am. Coll. Cardiol. Img.,
April 1, 2011;
4(4):
430 - 431.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Nakazawa, F. Otsuka, M. Nakano, M. Vorpahl, S. K. Yazdani, E. Ladich, F. D. Kolodgie, A. V. Finn, and R. Virmani
The Pathology of Neoatherosclerosis in Human Coronary Implants: Bare-Metal and Drug-Eluting Stents
J. Am. Coll. Cardiol.,
March 15, 2011;
57(11):
1314 - 1322.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Niccoli, R. A. Montone, G. Ferrante, and F. Crea
The Evolving Role of Inflammatory Biomarkers in Risk Assessment After Stent Implantation
J. Am. Coll. Cardiol.,
November 23, 2010;
56(22):
1783 - 1793.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. E. Muller, N. J. Weissman, and E. M. Tuzcu
The Year in Intracoronary Imaging
J. Am. Coll. Cardiol. Img.,
August 1, 2010;
3(8):
881 - 891.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. W. Lee, S. J. Kang, D. W. Park, S. H. Lee, Y. H. Kim, J. J. Kim, S. W. Park, G. S. Mintz, and S. J. Park
Intravascular Ultrasound Findings in Patients With Very Late Stent Thrombosis After Either Drug-Eluting or Bare-Metal Stent Implantation
J. Am. Coll. Cardiol.,
May 4, 2010;
55(18):
1936 - 1942.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. K. Pendyala, X. Yin, J. Li, J. P. Chen, N. Chronos, and D. Hou
The First-Generation Drug-Eluting Stents and Coronary Endothelial Dysfunction
J. Am. Coll. Cardiol. Intv.,
December 1, 2009;
2(12):
1169 - 1177.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Nakazawa, M. Vorpahl, A. V. Finn, J. Narula, and R. Virmani
One step forward and two steps back with drug-eluting-stents from preventing restenosis to causing late thrombosis and nouveau atherosclerosis.
J. Am. Coll. Cardiol. Img.,
May 1, 2009;
2(5):
625 - 628.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. Chandrashekhar, M. J. Kern, and J. Narula
Devices, biology, imaging, and the regulatory processes...
J. Am. Coll. Cardiol. Img.,
May 1, 2009;
2(5):
670 - 673.
[Full Text]
[PDF]
|
 |
|
|