Advertisement
top banner image  

topleft corner image     top right corner image
 
ACCF/AHA Clinical Guidelines and Statements

CME logo image
bullet
bullet
bullet
bullet

JACC Homepage JACC Interventions Homepage
Still not a subscriber to JACC Imaging or JACC Interventions?

take action
bullet
bullet
bullet
bullet
bullet
bullet
bullet
bullet

acc links
bullet
bullet
bullet
bullet
bullet
bullet
bullet
bullet
bullet

jacc imaging image
bullet
bullet
bullet
bullet

     top nav image

     

J Am Coll Cardiol Img, 2009; 2:1226-1237, doi:10.1016/j.jcmg.2009.08.004
© 2009 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Online Appendix
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Naqvi, T. Z.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Naqvi, T. Z.

State-of-the-Art Paper

Echocardiography in Percutaneous Valve Therapy

Tasneem Z. Naqvi, MD*

Echocardiography Laboratory, University of Southern California, Keck School of Medicine, Los Angeles, California


    Abstract
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
Echocardiography has played a critical role in valve reconstructive surgery and more recently in developments in percutaneous techniques for mitral valve repair and aortic valve implantation. A combination of transthoracic echocardiography and transesophageal echocardiography (TEE) provide diagnostic and screening data pre-procedure, intraprocedural guidance, and assessment of valve function and left ventricular reverse remodeling post-percutaneous valve procedures. The role of intracardiac echocardiography and live 3-dimensional TEE in percutaneous valve interventions is evolving. This review summarizes the role of echocardiography during percutaneous device-based valve procedures.

Key Words: percutaneous valve repair • percutaneous valve implantation • transesophageal echocardiography • transthoracic echocardiography • intracardiac echocardiography • 3-dimensional echocardiography

Abbreviations and Acronyms
  3D = 3-dimensional
  ICE = intracardiac echocardiography
  LA = left atrial, left atrium
  LV = left ventricular
  MR = mitral regurgitation
  MV = mitral valve
  PV = paravalvular
  TEE = transesophageal echocardiography
  TTE = transthoracic echocardiography


Proliferation of percutaneous technology for treatment of structural heart disease has led to a demand for online imaging with high spatial and temporal resolution and has placed echocardiography in the forefront as a diagnostic and therapeutic imaging modality. Recent developments in successful percutaneous aortic valve implantation (1,2), pulmonic valve implantation (3), coronary sinus stent placement for tightening of mitral annulus (4), as well as percutaneous edge-to-edge repair of the mitral valve (MV) (5) in patients with mitral regurgitation (MR) promise a proliferation of percutaneous catheter-based techniques for treatment of valvular heart disease (6). This therapy has a role especially in patients who are poor surgical candidates due to advanced age, poor cardiac function, or multiple comorbidities.

This paper focuses on the role of echocardiography during recently developed percutaneous MV repair and aortic and pulmonic valve implantation procedures. Three-dimensional (3D) echocardiography and intracardiac echocardiography (ICE) during established procedures such as balloon mitral valvuloplasty as well as their evolving role in recently introduced percutaneous valve interventions are briefly discussed.

Although fluoroscopy and contrast cineangiography have been used successfully for interventions within the coronary arteries, poor soft-tissue contrast resolution limits their ability to visualize intracardiac anatomy that is necessary for percutaneous valve procedures, demanding alternative imaging modalities for procedural guidance. Fluoroscopy and angiography can provide reliable guidance during percutaneous aortic valve implantation and coronary sinus stent placement; however, most centers also use transesophageal echocardiography (TEE) for aortic valve implantation. Percutaneous repair of complex structures such as the MV requires a clear delineation of intracardiac anatomy in multiple dimensions to facilitate catheter manipulation relative to cardiac chambers and valves, to guide the device to the desired target site on the valve, and to evaluate valve anatomy, valve gradients, and regurgitation after device deployment and is heavily dependent on TEE guidance during repair. Although other imaging modalities such as magnetic resonance imaging (7) are undergoing rapid evolution, and data are emerging on its potential role as online imaging, at present, echocardiography is the most readily available, portable, online imaging guide during percutaneous interventions. Please refer to the Online Appendix for an overview of the echocardiographic imaging modalities.


    Echocardiography in balloon mitral valvuloplasty
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
Echocardiography, both transthoracic echocardiography (TTE) and TEE, has an established role in MV percutaneous balloon valvuloplasty (8,9). TTE can be used as a stand-alone imaging modality with minimum use of fluoroscopy during mitral valvuloplasty (10). TEE is superior to TTE in evaluation of the left atrial (LA) appendage; guidance for transseptal puncture; evaluation of MV leaflets, commissures, and chordae; and assessment of residual atrial septal defect. TEE should be used for exclusion of LA thrombus and/or with an inexperienced interventionalist. Live 3D TEE can provide excellent patient selection and guidance by providing surgical views of the LA appendage, LA, interatrial septum, MV, and chords and provides a MV model depicting leaflet and annular geometry, leaflet angles, and surface area (Online Fig. E1, Fig. 1, Online Videos 1A, 1B, and 2). Three-dimensional TTE and TEE provide more accurate assessment of MV area (Online Video 2) than the planimetered MV area derived from 2D images, whereby the ultrasound beam may not transect the valve in the correct plane, or by the pressure half-time Doppler method, which is unreliable in the immediate post-valvuloplasty phase (11). During MV balloon valvuloplasty, 3D TEE can evaluate leaflet tear and its extent better than TTE, 2D TEE, or ICE (12). ICE has been used successfully in conjunction with TTE during percutaneous mitral valvuloplasty (13); however, it does not provide multiplanar assessment of the MV.


Figure 1
View larger version (30K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1 3D TEE of the MV in Mitral Stenosis

Three-dimensional (3D) volumetric transesophageal echocardiography (TEE) view showing mitral valve (MV) orifice visualized from the left ventricular (LV) side in a patient with mitral stenosis in A and the corresponding model reconstructed from 3-dimensional (3D) image dataset in B. Mitral annular shape, circumference, mitral leaflet surface area, and aorto-mitral angle are displayed in B. Curved yellow line in B is the mitral coaptation line. Also see Online Videos 1A, 1B, and 2. A = anterior; Ao = aortic root; Ant = anterior; AL = anterolateral commissure; P = posterior; PM = posteromedial commissure; Post = posterior.

 

    Echocardiography in paravalvular leak repair
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
Paravalvular (PV) regurgitation is seen with mechanical and bioprosthetic valves. Interrogation in multiple angles including off-axis views is required to determine the location and severity of the regurgitation. PV regurgitation (or leak) is characterized by Doppler flow outside the sewing ring of the valve, often in an eccentric direction. TTE may be adequate for most of the qualitative and quantitative information needed to evaluate aortic PV leaks. TEE complements TTE in technically difficult studies and in evaluating posterior aortic PV leaks. Because of artifacts and reverberations, prosthetic MV PV regurgitation, however, may be missed on TTE, and TEE is required for diagnosis, location, and assessment of severity. The proportion of the circumference of the sewing ring occupied by the jet gives an approximate guide to severity. MR jet width at origin of 1 to 2 mm, 3 to 6 mm, and >6 mm, respectively, defines mild, moderate, and large PV leak (14). A combination of semiquantitative and quantitative parameters similar to those used for native valve regurgitation may be used although eccentric jets may make quantitation difficult. Three-dimensional color Doppler may improve quantitation of PV regurgitation. TEE helps evaluate contraindications to percutaneous closure of PV leaks, such as mechanical instability of the prosthetic valve, intracardiac thrombus, and endocarditis (15). Real-time 3D TEE is far superior to 2D TEE in evaluation of location and extent of PV leak (Fig. 2, Online Videos 3A, 3B, and 4). TEE plays a critical role in the percutaneous closure of PV leaks by providing guidance on location of transseptal puncture, particularly in patients with calcified interatrial septum not uncommon with multiple prior valve surgeries (Figs. 3A and 3B), facilitating placement of the guidewires across the PV defect (Figs. 3C and 3D), providing guidance on catheter and guide manipulation to approach the defect perpendicularly, confirming adequate seating of the device across the defect before deployment, verifying normal prosthetic valve leaflet motion (Online Video 5A), assessing severity of residual PV regurgitation (Figs. 3F to 3I), evaluating residual atrial septal defect after device deployment, and detecting procedural complications promptly, such as development of thrombus on catheters and development of pericardial effusion. Using more than 1 Amplatzer septal occluder device (atrial septal defect closure device used off-label for PV closure) potentially increases the risk of device dislodgement with embolization, and lead to interference with prosthetic leaflet motion (Online Video 5A) and disruption of the prosthetic valve. Isolated reports on use of 3D TEE during closure of PV leak exist (16). Although the incremental value of 3D over 2D TEE during device closure of PV leak is not established, 3D TEE may allow procedure planning, including procedure feasibility by better assessment of location and extent of PV leak, and may shorten procedure time by facilitating catheter manipulation, device sizing and positioning.


Figure 2
View larger version (42K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2 2D and 3D TEE in PV Leak

Mid-esophageal 2D TEE view at 0° showing paravalvular (PV) leak located anteromedially between St. Jude's aortic and mitral prostheses. St. Jude's mitral valve disks in the closed position are shown by white arrows in A. B is the 3D TEE view showing St. Jude's mitral valve disks in the open position from the atrial aspect. A PV hole is seen at the 10 o'clock position (white arrow). The location of the PV leak made percutaneous repair nonfeasible. Also see Online Videos 3A, 3B, and 4. LA = left atrium; RA = right atrium; other abbreviations as in Figure 1.

 

Figure 3
View larger version (43K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3 TEE During Percutaneous Closure of PV Leak

A to D show PV leaks by white arrows in a 72-year-old female with 4 prior MV surgeries. Paravalvular leak is shown by white arrows. Large leak is shown at baseline (A), moderate leak after first device deployment (B), mild leak after balloon (*) dilation lateral to the first device (C), and after 2 Amplatzer devices (D). E to H show detection of potential complications with TEE during procedure, shown by arrows. E shows direction of Brockenbrough needle towards the aortic root, F shows atrial tissue attached to the sheath (withdrawn subsequently with the sheath), G shows passage of wire across the St. Jude's mitral valve (black arrow), and H shows resulting severe MR (white arrow). Also see Online Videos 5A and 5B. Ao = aorta; other abbreviations as in Figures 1 and 2.

 

    Echocardiography in MV repair
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
TTE provides accurate quantification of MR severity and is able to determine etiology of MR as degenerative, ischemic, or functional. Quantitative assessment of MR by vena contracta (width of MR jet at its origin) and measurement of effective regurgitant orifice area and regurgitant volume is now the gold standard for MR quantitation (17) (Online Fig. E2) and has been used for the first time in a multicenter setting in Phase I and Phase II EVEREST (Endovascular Valve Edge-to-Edge REpair STudy) trials (6). TTE often provides limited information on valve reparability. Three-dimensional TTE may improve MV assessment although resolution of 3D TTE remains an important limitation (Online Fig. E3). At present, percutaneous MV repair technique by the edge-to-edge technique aims to repair MR originating from the A2 and P2 scallops of MV rather than commissures or posteriorly or anteriorly located MV scallops. TEE evaluates location of diseased mitral scallop/s by using 2D and color Doppler in multiple imaging planes (Online Fig. E4), by location of flow convergence (Online Figs. E4 to E7), and by assessment of site of origin of MR jet. MR jet origin in the short-axis view is critical to evaluate location and severity of pathology and complements information obtained by long-axis views (Online Fig. E8).

The first approach to percutaneous MV repair is the edge-to-edge technique, which creates a double MV orifice replicating the surgical intervention pioneered by Alfieri et al. (18). Preliminary clinical results obtained in over 100 patients from percutaneous edge to edge repair using a clip (Evalve, Inc., Menlo Park, California) in Phase I (6) and II (19) studies suggest that in expert hands, the success rate of the technique is high (80% to 90%), and the degree of MR can be reduced to mild in two-thirds of cases. The risk is low in experienced centers. In patients in whom the procedure was successful, two-thirds of the cases remained event-free after 3 years. Besides assessment of involved scallops, screening by echocardiography involves measurement of coaptation depth and coaptation length in ischemic MR (Online Fig. E8) and of flail gap (Online Fig. E9) and flail width (Online Fig. E10) in degenerative MR.

In the catheterization laboratory, TEE is the primary imaging modality used for procedural guidance of MV repair using the Evalve clip. TEE is able to visualize all components of the clip delivery system (Figs. 4 to 9,GoGoGoGoGo Online Videos 6A, 6B, and 6C). TEE guides puncture of the posterior and superior portion of the interatrial septum, thereby allowing perpendicular alignment of device in the plane of the posteriorly located MV (Fig. 4). By visualization of guide and device catheter tips, TEE helps steer these devices in the appropriate direction and ensures minimal device–endocardial contact. TEE guides advancement of the therapy catheter towards the center of pathology by placing it within the center of maximum MR jet. Steering of the device assembly is performed in the mediolateral and anteroposterior planes using 2- and 3-chamber views, respectively (Fig. 6). The actual procedure of opening the clip in the LA, its advancement into the LV, its correct alignment so the device arms are at right angles to the MV coaptation, and actual leaflet capture are all guided by TEE (Online Videos 6A, 6B, and 6C). TEE directs the decision to release the clip in case of suboptimal MV leaflet capture or whether the procedure should be abandoned in cases of minimal MR reduction once leaflets are grasped. TEE confirms an adequate result by reduction in the MR grade to less than moderate and by visualizing anterior and posterior MV leaflet anatomy. TEE is able to determine the immediate effect of MR reduction on cardiac physiology, including MV gradients, pulmonary venous flow pattern, right ventricular systolic pressure, and residual MV area before the clip is finally deployed (Fig. 9). TEE determines the need for a second clip by assessing the severity of residual MR and guides placement of the guidewire and therapy catheter in the correct orifice of a double orifice MV (Fig. 10, Online Videos 7A and 7B). TEE confirms the final MR grade and size of residual atrial septal defect before the completion of the procedure. TEE allows immediate detection of procedural complications such as development of thrombus on catheters, pericardial effusion, and tangling of device with chordae. Finally, echocardiography evaluates MR severity during follow-up, device stability and effect on LV size and function, and pulmonary artery pressure. Isolated case examples on the use of live 3D TEE during MV repair are beginning to emerge (16). The incremental value of 3D TEE in this procedure has not been examined, but it may guide perpendicular alignment of therapy catheter to the MR jet in patients with markedly dilated LA and may significantly shorten procedure time by providing surgical-type views of mitral apparatus.


Figure 4
View larger version (57K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4 TEE During Initial Stages of Percutaneous MV Repair by Evalve Clip

Mid-esophageal transesophageal views used for guided transseptal puncture during percutaneous edge to edge MV repair. (A) Short-axis view at the base (showing the anterior–posterior portion of the interatrial septum with tenting (white arrow) at the junction of septum primum with septum secundum or the edge of the fossa. (B) Bicaval view showing the superior–inferior portion of the interatrial septum. (C) Bicaval view with tenting at the junction of ostium primum with ostium secundum (white arrow). (D) Mid-esophageal 4-chamber view (for assessing height of the tenting site above the MV plane) to allow perpendicular approach of the guide and device catheter towards the MV. Also see Online Videos 6A, 6B, and 6C. IVC = inferior vena cava; SVC = superior vena cava; other abbreviations as in Figure 2.

 

Figure 5
View larger version (61K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 5 TEE During Early Stages of Percutaneous MV Repair by Evalve Clip

TEE views at the mid-esophageal level used to guide early stages of Evalve edge-to-edge repair. Transseptal puncture at the superoposterior interatrial septum is shown in the mid-esophageal short-axis view at the base of the heart in A and 4-chamber view in B (white arrowhead). Note the needle tip in the LA in C (white arrowhead), 22-F guide delivery sheath in the LA in D (white arrowhead) and tip of the device delivery guide and of the therapy catheter in E and F (white arrowheads). Also see Online Videos 6A, 6B, and 6C. Ao = aorta; other abbreviations as in Figures 1 and 2.

 

Figure 6
View larger version (75K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 6 TEE During Mid-Stages of Percutaneous MV Repair by Evalve Clip

TEE views at the mid-esophageal level used to guide middle stages of Evalve edge-to-edge repair. 2-chamber (A) and 3-chamber views (B) are used to navigate the tip of the device (arrowheads) toward the middle of the MV in the mediolateral (A) and anteroposterior plane (B). White arrows in A and B point to the MV leaflets. Device tip is shown in the middle of MR jet in C and D by white arrowheads. Also see Online Videos 6A, 6B, and 6C. Abbreviations as in Figures 1 and 2.

 

Figure 7
View larger version (83K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 7 TEE During Mid- to Late Stages of Percutaneous MV Repair by Evalve Clip

TEE views at the mid-esophageal and deep transgastric level used to guide middle to later stages of Evalve edge-to-edge repair. Anterior leaflet is on the right and posterior leaflet on the left. Open clip is shown in the LA above the MV leaflets (white arrows) in A. The corrugated surface of the grippers and the open Dacron arms are shown (white asterisks). Open clip advanced into the LV through the MV is shown in B. Grippers are shown folded upward and the Dacron arms opened horizontally (white asterisks). C shows that posterior and anterior leaflets well within the grippers and the closed Dacron arms of the clip. D shows the clip along with the captured anterior and posterior leaflets after release of the clip from the device assembly. Also see Online Videos 6A, 6B, and 6C. AV = aortic valve; other abbreviations as in Figures 1 and 2.

 

Figure 8
View larger version (24K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 8 TEE During Late Stages of Percutaneous MV Repair by Evalve Clip

A transgastric short-axis view at the mitral valve (MV) level showing clip arms parallel to the plane of coaptation of anterior and posterior MV leaflets (white horizontal arrow) in A. B shows a 90° rotation of the clip arms so these are perpendicular to MV coaptation (white vertical arrow) before the clip is pulled back for mitral leaflet capture. MV scallops are labeled in diastole in A. Also see Online Videos 6A, 6B, and 6C.

 

Figure 9
View larger version (73K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 9 TEE Doppler Evaluation During Evalve Clip Deployment

Mid-esophageal views showing 2D and Doppler evaluation performed after the clip is released before decision on the adequacy of capture or the need for a second clip is made. Multiple views and angulation are used to ensure that eccentric jets are not missed. A shows apical 3-chamber view with color Doppler. No color Doppler evidence of residual MR after clip deployment (white arrow) is shown in A. B shows continuous wave Doppler of mitral inflow to evaluate peak and mean MV gradients to ensure lack of mitral stenosis. C and D are pulsed wave Doppler signals obtained from the left inferior pulmonary vein showing systolic flow reversal (white arrows) pre-clip deployment in C and systolic (S) dominant flow pattern in the same pulmonary vein post-clip deployment in D. Also see Online Videos 6A, 6B, and 6C.

 

Figure 10
View larger version (81K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 10 TEE Evaluation of Residual MR After Evalve Clip Deployment

Mid-esophageal TEE views in the mediolateral plane showing significant residual MR jet (white arrow) lateral to the Evalve clip in A. Two trivial MR jets medial to the clip are also shown. B shows a diastolic frame with a double orifice mitral inflow (white arrowheads). C is obtained after second clip deployment and shows no residual MR jet lateral to the second clip, and D shows double mitral inflow with 2 orifices (shown by white arrow heads) separated by a wider distance due to 2 clips in D versus 1 clip in B. Also see Online Videos 7A and 7B.

 
The second possible approach of mitral annuloplasty, which is achieved by introducing a constraining device in the coronary sinus located in the vicinity of the mitral annulus can be accomplished by fluoroscopy and coronary sinus angiography. Preliminary efficacy data suggest some reduction in the degree of MR in animals (20) and humans (5). Although TEE can show the coronary sinus ostium and its diameter in the proximal and mid- to distal course for stent sizing, assessment of coronary sinus length and its relation to the mitral annulus and to the circumflex coronary artery remains difficult by TEE. TTE and TEE can nevertheless determine acute or chronic mitral annular diameter reduction with coronary sinus stent placement and its effect on MR severity.


    ICE during percutaneous MV repair
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
There is no published human experience with ICE during percutaneous MV repair or aortic valve implantation. This author's experience with ICE in animal experiments suggests that ICE can be an adjunctive if not a sole imaging modality during percutaneous valve interventions (21) (Fig. 11, Online Video 8). ICE along with TEE may facilitate edge-to-edge MV repair procedure by visualizing intracardiac structures that may be difficult to delineate due to shadowing from calcification or prosthetic material during TEE.


Figure 11
View larger version (25K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 11 Intracardiac Echocardiography During Percutaneous MV Therapy

Intracardiac views obtained by Acunav catheter in the right atrium of a swine. A shows tenting of the interatrial septum (white arrow) by the Brockenbrough needle. B shows J-shaped tip of guidewire in the LA after transseptal puncture. C shows anterior and posterior leaflets of the MV with the ICE catheter advanced across the interatrial septum into the LA and the transducer facing down. D shows a short-axis view of the MV at the base with a central suture and clip (white arrow) and a double orifice MV created after the deployment of suture and clip (Edwards Lifesciences, Irvine, California). The SAX view was obtained by advancing the ICE catheter across the tricuspid and pulmonic valves. E shows aortic root, left main coronary artery (white arrow), and LV, and F is a 4-chamber view obtained by advancing the ICE catheter tip into the right ventricle. Also see Online Video 8. Abbreviations as in Figures 1 and 2.

 

    Echocardiography in percutaneous aortic valve implantation
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
Percutaneous aortic valve implantation is an emerging alternative for inoperable patients with severe aortic stenosis and can be deployed using an antegrade (1) or retrograde (2,22) approach. Presently, there are 2 catheter-based treatment systems (the Cribier-Edwards Aortic Bioprosthesis [2] and the CoreValve ReValving System) utilizing either a balloon-expandable or a self-expanding frame that unfolds a pericardial tissue valve within the displaced diseased aortic valve. Current Edwards Sapien series and CoreValves have CE mark approval in Europe. Compared with surgical aortic valve replacements, percutaneous valve implantation leads to lower mean gradients but increased incidence of mild or moderate PV leak (23). TTE is essential for pre-procedure screening. Although the procedure can be performed under fluoroscopic guidance alone, TEE can accurately measure aortic valve annulus, LV outflow tract, and ascending aorta to assist in selection of prosthetic valve size. A difference of up to 4 mm between the TTE and the TEE annulus measurements can occur and may lead to a change in valve size (24). TEE provides assessment of LV and valve function and thoracic aortic anatomy. Severe, mobile plaque supports utilization of the transapical approach, which avoids manipulation of large catheters in the aorta. Three-dimensional TEE is particularly invaluable in evaluating aortic atheroma (Online Fig. E11).

During implantation, TEE evaluates the exact position of the deployment catheter and valve, which is critical for valve function. The 14- or 16-mm long Edwards prosthesis relies on traction with the native annulus for post-deployment stability. Although the prosthesis must be positioned distal enough to permanently stent open the native aortic valve cusps, slightly more than one-half of the prosthesis should remain on the LV side of the aortic valve annulus. Deployment of the apparatus at the level of the sinuses of Valsalva is too distal, may lead to aortic regurgitation, and risks valve embolization. Ascending aortic dilation is therefore not a contraindication for the Edwards valve since the valve sits inside the native aortic annulus (25). Early assessment of PV regurgitation is crucial. Significant transvalvular aortic regurgitation suggests overexpansion of the prosthesis, which may require deployment of a second prosthetic valve within the first. Following prosthetic valve deployment, TEE can immediately assess prosthetic valve position, in relation to the LV outflow tract and aortic valve plane, prosthetic valve leaflet mobility, valve area, and gradients and presence of central and PV regurgitation. Multiple views are essential to determine the site and degree of aortic regurgitation post-implant and the need for further balloon dilation. Acoustic shadowing off the stent may make evaluation of PV leak difficult. The short-axis view most reliably distinguishes PV from transvalvular aortic regurgitation. This distinction is difficult to make by fluoroscopy and aortic root contrast injection. TEE greatly facilitates detection of procedural complications such as presence of thrombi on catheters, development of pericardial effusion, any interference of the procedure with MV motion, development of MR, possible compression of coronary ostia by native aortic valve leaflets (by showing new wall motion abnormalities), and aortic hematoma or dissection during or after the procedure. Real-time 3D TEE may provide superior spatial visualization of the cardiac structures and facilitate the detection of procedure-related complications that might improve patient outcome (26). It may be helpful in evaluating coronary ostia in relation to the stented valve (Online Fig. E12).


    Intracardiac echocardiography in percutaneous aortic valve implantation
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
This author has used ICE as an imaging guide in swine during the development of a percutaneous aortic valve (27). ICE allowed accurate measurement of aortic annulus, assisted with placement of the device within the aortic annulus, helped in assessment of PV leak post-valve deployment and the need for further balloon expansion, and in assessment of post-deployment gradients (Fig. 12, Online Videos 9A, 9B, and 9C).


Figure 12
View larger version (91K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 12 Intracardiac Echocardiography During Percutaneous AV Therapy

ICE imaging during percutaneous aortic valve (Edwards Lifesciences) replacement obtained in a pig with the ICE catheter tip placed in the right atrium. Wire across the aortic valve (white arrow) placed via a retrograde approach in A, delivery sheath advanced across the aortic valve and into the LV outflow tract in B, balloon expansion of the stent at the level of the aortic valve in C, incomplete stent deployment with a space between the stent post and the posterior aortic root (white asterisk) and flow through this space in D, further balloon inflation for stent expansion in F. Also see Online Videos 9A, 9B, and 9C. Ao = aortic root.

 

    Echocardiography in pulmonic valve implantation
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
Currently available percutaneous pulmonic valve is a balloon-expandable valve stent composed of a bovine jugular valve mounted in a platinum/iridium stent (Medtronic Corp./NuMED Inc., Medtronic Inc., Minneapolis, Minnesota) and is largely implanted in children with complex congenital heart disease and prior right ventricular to pulmonary artery valved conduits with conduit valve stenosis and/or regurgitation (28). The major drawback in pulmonary valve replacement is limitation in bovine jugular venous valve size, which rarely exceeds 18 to 22 mm in diameter. Echocardiography plays a diagnostic role pre-procedure and post-procedure to evaluate implanted pulmonic valve function. Fluoroscopy and cineangiography remain key imaging modalities during valve deployment. ICE has been used in isolated case reports and provides adequate anatomic and physiologic information to guide percutaneous pulmonic valve placement (29).


    Conclusions
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
Recent studies have shown successful percutaneous MV repair by edge-to-edge procedure and stent-mounted aortic and pulmonic valve implantation. The real-time guidance of this procedure requires a unique and intense collaboration between echocardiologist and interventionalist not hitherto seen in other catheterization lab procedures or intraoperative TEE (30). This collaboration includes use of common vocabulary, training of the interventionalist on basic echocardiographic views critical for the procedure, and possession of unique interventional imaging skill by the echocardiologist. Besides conventional diagnostic echocardiography, hybrid views showing endovascular devices and their relationship to cardiac structures and command on 3D reconstruction of cardiac anatomy from 2D images is required. Limitations of 2D TEE imaging include shadowing from devices, loss of imaging plane from respiratory motion in an intubated patient, and suboptimal images, especially later in the procedure due to stomach air, poor contact of probe with the stomach wall due to secretions, and reduction in heart size from blood loss. Further developments in delivery technology, valve design improvements, and availability of follow-up data will lead to proliferation of percutaneous valve technology and in turn development of interventionists dedicated to treatment of structural heart disease and echocardiologists dedicated to interventional echocardiography.


    Appendix
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 
For an overview of the echocardiographic imaging modalities, accompanying Figures E1 to E12, and accompanying Videos 1A to 9C with their legends, please see the online version of this paper.


Figure 1A
View larger version (64K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 1A Video 1A

TEE view obtained by 2D imaging in a patient with mitral stenosis. Note marked spontaneous contrast in an enlarged LA and left atrial appendage.

 


Figure 1B
View larger version (72K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 1B Video 1B

TEE 3D volumetric imaging with anterior wall of LA removed. Left atrial appendage without thrombus, mitral annulus, MV leaflets and posteromedial left atrial wall are shown.

 

Figure 2
View larger version (86K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 2 Video 2

3D TEE video clip in the same patient as Video 1 showing rheumatic stenotic MV from LV side.

 

Figure 3A
View larger version (60K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 3A Video 3A

Video clip of the mid esophageal 2D TEE view of St Jude's MV showing normal disk motion and a paravalvular leak located anteromedially.

 

Figure 3B
View larger version (31K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 3B Video 3B

Video clip of the midesophageal 3D TEE view showing paravalvular regurgitation on 3D color Doppler.

 

Figure 4
View larger version (89K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 4 Video 4

Video clip of the mid esophageal 3D TEE view of a St Jude's MV from the atrial aspect along with a paravalvular hole at 10° clock position.

 

Figure 5A
View larger version (55K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 5A Video 5A

A video clip showing a mid esophageal TEE view with restricted motion of the lateral St Jude's MV disk motion caused by the second Amplatzer device. This restriction disappeared after device was pulled back toward the mitral annular defect.

 

Figure 5B
View larger version (57K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 5B Video 5B

A video clip in the deep esophageal location showing 2 Amplatzer devices and a residual mild paravalvular leak lateral to the second Amplatzer device.

 

Figure 6A
View larger version (53K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 6A Video 6A

3D TTE video clip of a myxomatous MV from the atrial aspect. Prolapse of all scallops of both MV leaflets is shown.

 

Figure 6B
View larger version (34K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 6B Video 6B

3D TTE video clip of a myxomatous MV from the LV aspect.

 

Figure 6C
View larger version (49K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 6C Video 6C

Video clip in the mid esophageal 3-chamber view showing severe eccentric anterior MR due to P2 prolapse.

 

Figure 7A
View larger version (64K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 7A Video 7A

Video clip in the mid esophageal 3 chamber view showing MV leaflet capture and MV leaflets sandwiched between gripper and each side arm of the E valve clip.

 

Figure 7B
View larger version (69K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 7B Video 7B

A video clip in the mid esophageal 3 chamber view showing no residual MR after E valve clip deployment.

 

Figure 8
View larger version (36K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 8 Video 8

Video clip shows significant residual MR lateral to the first E valve clip in the 2-chamber view.

 

Figure 9A
View larger version (73K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 9A Video 9A

Video clip during percutaneous aortic valve replacement in a swine model. Stent inflation with a balloon during deployment of an aortic valve using a retrograde approach via a left femoral cut down.

 

Figure 9B
View larger version (66K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 9B Video 9B

Incomplete stent deployment with residual flow between aortic wall and posterior stent.

 

Figure 9C
View larger version (77K):
[in this window]
[in a new window]
[Download PPT slide]
 
Video 9C Video 9C

Video clip showing second balloon expansion of the stent. D shows normally functioning aortic valve with complete opposition to the aortic root.

 


    Acknowledgments
 
The author would like to thank the following physicians for procedures that helped collect some of the images and movies shown in this manuscript: Saibal Kar, MD, from Cedars Sinai Heart Institute, Los Angeles, California, for Evalve MV clip repairs in humans; Maurice Buchbinder, MD, from San Diego Cardiovascular Associates, San Diego, California, and Francesco Maisano, MD, from San Raffaele Scientific Institute, Milan, Italy, for Percutaneous MV suture repair in swine; Raj Makkar, MD, from Cedars Sinai Heart Institute, Los Angeles, California, for Percutaneous aortic valve replacement in a swine; Ray Matthews, MD, from University of Southern California, Los Angeles, California, for Paravalvular leak repair in a human. The author would also like to thank Evalve, Redwood, California, and Edwards Lifesciences, Irvine, California, for assistance with some interventional procedures.


    Footnotes
 
Dr. Naqvi is a consultant for Edwards Lifesciences and Micardia Corporation.

* Reprint requests and correspondence: Dr. Tasneem Z. Naqvi, 1510 San Pablo Street, 322, Cardiology Division, Keck School of Medicine, University of Southern California, Los Angeles, California 91730 (Email: tnaqvi{at}usc.edu).

Manuscript received July 28, 2009; revised manuscript received August 17, 2009, accepted August 21, 2009.


    REFERENCES
 Top
 Abstract
 Echocardiography in balloon...
 Echocardiography in paravalvular...
 Echocardiography in MV repair
 ICE during percutaneous MV...
 Echocardiography in percutaneous...
 Intracardiac echocardiography in...
 Echocardiography in pulmonic...
 Conclusions
 Appendix
 REFERENCES
 

  1. Cribier A, Eltchaninoff H, Tron C, et al. Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience J Am Coll Cardiol 2006;47:1214-1223.[Abstract/Free Full Text]
  2. Webb JG, Chandavimol M, Thompson CR, et al. Percutaneous aortic valve implantation retrograde from the femoral artery Circulation 2006;113:842-850.[Abstract/Free Full Text]
  3. Schreiber C, Horer J, Vogt M, et al. A new treatment option for pulmonary valvar insufficiency: first experiences with implantation of a self-expanding stented valve without use of cardiopulmonary bypass Eur J Cardiothorac Surg 2007;31:26-30.[Abstract/Free Full Text]
  4. Webb JG, Harnek J, Munt BI. Percutaneous transvernous mitral annuloplasty: initial human experience with device implantation in the coronary sinus Circulation 2006;113:851-855.[Abstract/Free Full Text]
  5. Feldman T, Wasserman HS, Herrmann HC, et al. Percutaneous mitral valve repair using edge-to-edge technique: six month results of the EVEREST Phase I Clinical Trial J Am Coll Cardiol 2005;46:2134-2140.[Abstract/Free Full Text]
  6. Vassiliades Jr. TA, Block PC, Cohn LH, et al. The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI). Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA). J Am Coll Cardiol 2005;3:1554-156045.
  7. Kuehne T. Cardiac interventions guided by magnetic resonance imaging Heart Metab 2007;34:19-23.
  8. Robinson NM, Thomas MR, Jewitt DE, Monaghan MJ. The value of transthoracic echocardiography during percutaneous balloon mitral valvuloplasty J Am Soc Echocardiogr 1995;8:79-86.[CrossRef][Medline]
  9. Park SH, Kim MA, Hyon MS. The advantages of on-line transesophageal echocardiography guide during percutaneous balloon mitral valvuloplasty J Am Soc Echocardiogr 2000;13:26-34.[Web of Science][Medline]
  10. Vijay Trehan V, Mukhopadhyay S, Nigam A, et al. Mitral valvuloplasty by Inoue balloon under transthoracic echocardiographic guidance J Am Society of Echocardiogr 2005;18:964-969.[CrossRef]
  11. Zamorano J, Perez de Isla L, Sugeng L, et al. Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: role of real-time 3D echocardiography Eur Heart J 2004;25:2086-2091.[Abstract/Free Full Text]
  12. Applebaum RM, Kasliwal RR, Kanojia A, et al. Utility of three-dimensional echocardiography during balloon mitral valvuloplasty J Am Coll Cardiol 1998;32:1405-1409.[Abstract/Free Full Text]
  13. Green NE, Hansgen AR, Carroll JD. Initial clinical experience with intracardiac echocardiography in guiding balloon mitral valvuloplasty: technique, safety, utility, and limitations Catheter Cardiovasc Interv 2004;63:385-394.[CrossRef][Web of Science][Medline]
  14. Vitarelli A, Conde Y, Cimino E, et al. Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography Heart 2004;90:539-544.[Abstract/Free Full Text]
  15. Bhindi R, Bull S, Schrale RG, Wilson N, Ormerod OJ. Surgery insight: percutaneous treatment of prosthetic paravalvular leaks Nat Clin Pract Cardiovasc Med 2008;5:140-147.[CrossRef][Web of Science][Medline]
  16. Hamilton-Craig C, Boga T, Platts D, Walters DL, Burstow DJ, Scalia G. The role of 3D transesophageal echocardiography during percutaneous closure of paravalvular mitral regurgitation J Am Coll Cardiol Img 2009;2:771-773.[Free Full Text]
  17. Zoghbi WA, Enriquez-Sarano M, Foster E, et al. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography J Am Soc Echocardiogr 2003;16:777-802.[CrossRef][Web of Science][Medline]
  18. Alfieri O, Maisano F, De Bonis M, et al. The double-orifice technique in mitral valve repair: a simple solution for complex problems J Thorac Cardiovasc Surg 2001;122:674-681.[Abstract/Free Full Text]
  19. Feldman T, Kar S, Rinaldi M, et al. Percutaneous mitral repair with the MitraClip system: safety and midterm durability in the initial EVEREST (Endovascular Valve Edge-to-Edge REpair Study) cohort J Am Coll Cardiol 2009;54:686-694.[Abstract/Free Full Text]
  20. Kaye DM, Byrne M, Alferness C, et al. Feasibility and short-term efficacy of percutaneous mitral annular reduction for the therapy of heart failure-induced mitral regurgitation Circulation 2003;108:1795-1797.[Abstract/Free Full Text]
  21. Naqvi TZ, Zarbatany D, Molloy, MD, Logan J, Buchbinder M. Intracardiac echocardiography for percutaneous mitral valve repair in a swine model J Am Soc Echocardiogr 2006;19:147-153.[CrossRef][Web of Science][Medline]
  22. Grube E, Laborde JC, Gerckens U, et al. Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study Circulation 2006;114:1616-1624.[Abstract/Free Full Text]
  23. Clavel MA, Webb JG, Pibarot P, et al. Comparison of hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis J Am Coll Cardiol 2009;53:1883-1891.[Abstract/Free Full Text]
  24. Moss RR, Ivens E, Pasupati S, et al. Role of echocardiography in percutaneous aortic valve implantation J Am Coll Cardiol Img 2008;1:15-24.[Abstract/Free Full Text]
  25. Billings IV FT, Kodali SK, Shanewise JS. Transcatheter aortic valve implantation: anesthetic considerations Anesth Analg 2009;108:1453-1462.[Abstract/Free Full Text]
  26. Janosi RA, Kahlert P, Plicht B, et al. Guidance of percutaneous transcatheter aortic valve implantation by real-time three-dimensional transesophageal echocardiography: a single-center experience Minim Invasive Ther Allied Technol 2009:142-148.
  27. Webb JG, Munt B, Makkar RR, Naqvi TZ, Dang N. Percutaneous stent-mounted valve for treatment of aortic or pulmonary valve disease Catheter Cardiovasc Interv 2004;63:89-93.[CrossRef][Web of Science][Medline]
  28. Bonhoeffer P, Boudjemline Y, Qureshi SA, et al. Percutaneous insertion of the pulmonary valve J Am Coll Cardiol 2002;39:1664-1669.[Abstract/Free Full Text]
  29. Chessa M, Butera G, Carminati M. Intracardiac echocardiography during percutaneous pulmonary valve replacement Eur Heart J 2008;29:2908.[Free Full Text]
  30. Silvestry FE, Rodriguez LL, Herrmann HC, et al. Echocardiographic guidance and assessment of percutaneous repair for mitral regurgitation with the Evalve MitraClip: lessons learned from EVEREST I J Am Soc Echocardiogr 2007;20:1131-1140.[CrossRef][Web of Science][Medline]



This article has been cited by other articles:


Home page
J Am Coll Cardiol ImgHome page
R. Bagur, J. Rodes-Cabau, D. Doyle, R. De Larochelliere, J. Villeneuve, J. Lemieux, S. Bergeron, M. Cote, O. F. Bertrand, P. Pibarot, et al.
Usefulness of TEE as the Primary Imaging Technique to Guide Transcatheter Transapical Aortic Valve Implantation
J. Am. Coll. Cardiol. Img., February 1, 2011; 4(2): 115 - 124.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
E. Altiok, M. Becker, S. Hamada, E. Grabskaya, S. Reith, N. Marx, and R. Hoffmann
Real-Time 3D TEE Allows Optimized Guidance of Percutaneous Edge-to-Edge Repair of the Mitral Valve
J. Am. Coll. Cardiol. Img., November 1, 2010; 3(11): 1196 - 1198.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Online Appendix
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Naqvi, T. Z.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Naqvi, T. Z.

Advertisement
 
   
 
home link current link search link archive link topics link cardiology careers link