JACC: Cardiovascular Imaging
Increased Iron Deposition Is Directly Associated With Myocardial Dysfunction in Patients With Sickle Cell Disease
Author + information
- Published online February 5, 2018.
Article Versions
- previous version (April 12, 2017 - 11:00).
- You are viewing the most recent version of this article.
Author Information
- Kana Fujikura, MD, PhD∗ (kfujikura{at}bwh.harvard.edu),
- Anjani D. Golive, MD,
- Tomo Ando, MD,
- Francisco M. Corado, MD,
- Sanyog G. Shitole, MBBS, MPH,
- Jorge R. Kizer, MD, MSc,
- Aman M. Shah, MD,
- Martin R. Prince, MD, PhD,
- Daniel M. Spevack, MD, MPH and
- Mario J. Garcia, MD
- ↵∗Cardiology Division, Department of Medicine, Montefiore Medical Center/Albert Einstein College of Medicine, 111 East 210th Street, Bronx, New York 10467
Cardiac toxicity from myocardial iron deposition has been well established in beta-thalassemia major (1). Among patients with thalassemia who are transfusion dependent, cardiac toxicity from myocardial iron deposition remains a major cause of mortality. Myocardial iron deposition, although less common, can also occur in frequently transfused patients with sickle cell disease (SCD) (2).
Magnetic resonance imaging (MRI) is the reference standard to evaluate myocardial iron overload and efficacy of the iron chelation therapy over time. Myocardial deformation analysis using speckle-tracking echocardiography (STE) has been increasingly adopted to assess left ventricular function. The aim of this study was to determine if myocardial iron concentration (MIC), estimated from T2* MRI, correlates with myocardial dysfunction assessed by STE.
Fifteen SCD patients who had abdominal MRI scans and echocardiography performed within a 1-year period were retrospectively selected. The abdominal MRI studies were acquired using 1.5- or 3-T scanners (Philips Healthcare, Andover, MA). All studies included at least 1 dual echo gradient echo. T2* was derived from the following equation: T2* = (TEout - TEin)/ln (SIin/SIout), where TE stands for time echo, ln for natural logarithm, SI for signal intensity, out for out-of-phase, and in for in-phase. MIC was estimated using the clinical calibration equation: [Fe] = 45.0 × (T2*)−1.22, with [Fe] in mg/g dry weight (dw) (3).
The associations between MIC and STE were evaluated. Statistical analysis was performed using SPSS version 21 (IBM Corporation, Armonk, New York). Spearman correlation coefficients were calculated, and a p value <0.05 was considered statistically significant. The 95% confidence interval for the Spearman correlation coefficient was calculated using Fisher z-transformation.
SCD patients median age was 34 years (range 21 to 70 years), 9 (60%) were women. MIC was 0.929 ± 0.832 mg/g dw (range 0.0171 to 2.77 mg/g dw). As shown in Table 1, conventional echocardiography indices of left ventricular systolic and diastolic function did not correlate with MIC. In contrast, radial STE parameters showed a strong association. In fact, in our study group, radial displacement <5 mm was found in 5 of 6 subjects with a MIC >1 mg/g, whereas radial displacement ≥5 mm was found in all subjects with a MIC <1 mg/g. In an age-matched control group with normal MIC, 9 of 10 showed radial displacement ≥5 mm.
Correlations Between MIC and Echocardiographic Variables
This preliminary study demonstrates a strong correlation between MIC and the presence of subclinical myocardial dysfunction, as determined by STE, in patients with SCD. These findings are noteworthy because the MIC values in our study subjects were only mildly elevated. Normal MIC has been previously reported as 0.34 mg/g dw (range 0.29 to 0.47 mg/g dw). In our SCD patient group, 8 subjects had a MIC >0.47 mg/g.
STE parameters have been previously evaluated in SCD. Barbosa et al. (4) showed that STE measures in SCD were similar to controls without SCD. In contrast, our study group had lower longitudinal and radial strains. This may be due to differences in the populations studied. The patients in the study by Barbosa et al. (4) were younger and were not evaluated for MIC, whereas our population included older patients with longer duration of disease.
Our study has some important limitations. First, it is a retrospective study with a small sample size. Second, T2* values were calculated from the myocardial signal obtained from abdominal MRI studies because they were more commonly indicated for the evaluation of symptoms. Accordingly, motion artifacts from MRI images acquired without electrocardiogram gating may have resulted in inaccuracies in determining MIC. Third, we used MRI images obtained by both 1.5- and 3-T scanners because of the limited number of study subjects with images from a single scanner. Although 3-T scanners are now commonly used, there is less clinical experience in measurement of MIC using 3-T.
These preliminary results showing a decrease in radial deformation detected by STE correlating with increased MIC in patients with SCD do not prove a causative relationship. However, given the known cardiac toxicity of myocardial iron, STE may identify iron overload at an early stage, potentially guiding chelating therapy. Larger prospective studies will be needed to investigate the association of MIC, STE, and adverse cardiac outcomes in patients with SCD as well as potential benefits from iron chelation.
Footnotes
Please note: The authors have reported that they have no relationships relevant to the contents of this paper to disclose.
- 2018 American College of Cardiology Foundation
References
- ↵
- ↵
- Wood J.C.,
- Tyszka M.,
- Carson S.,
- Nelson M.D.,
- Coates T.D.
- ↵
- Carpenter J.P.,
- He T.,
- Kirk P.,
- et al.
- ↵
- Barbosa M.M.,
- Vasconcelos M.C.,
- Ferrari T.C.,
- et al.